4 Channel Transformer Switchgear Fire Wire Partial Discharge Detector

4 Channel Transformer Switchgear Live Line Partial Discharge DetectorGDPD-414 adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684481). HVHIPOT company introduces international advanced PD detection technology to develop and produce portable and efficient PD inspection tools for

Featured Products

4 Channel Transformer Switchgear Live Line Partial Discharge Detector


GDPD-414 adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684481). HVHIPOT company introduces international advanced PD detection technology to develop and produce portable and efficient PD inspection tools for live high-voltage insulation equipment. It can flexibly configure various sensors according to different tested objects. TEV, AE and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; AE and UHF are suitable for detecting the insulation state of GIS; AE and HFCT are suitable for testing the insulation state of the cable. The built-in expert diagnosis system can analyze the test data and judge the discharge energy and possible parts. It is widely used in electric power and railway.


Features
 
  1. The whole machine adopts portable ABS engineering chassis. PD detection host, tablet/notebook, sensors, charger and signal cables are placed in the portable engineering chassis. The total weight is less than 8KG, easy for carrying and operating.
  2. Adopt self-developed high-speed DSP/FPGA sampling board, 4-channel synchronous data acquisition, signal processing, feature parameter extraction, data can be sent to the terminal by wire and wireless.
  3. Software system: analysis software based on ARM embedded system, display software based on windows system.
  4. A data acquisition host can simultaneously configure 4 channels of the same or different sensors, and can simultaneously collect and analyze 4 channels of signals.
  5. 6/8/16 channels can be configured according to customer's different demands.
  6. 8.1 inch tablet or Thinkpad notebook as optional
  7. The software system judges the discharge energy and location according to the detection data, and can display the PRPS and PRPD maps, ellipse diagrams, discharge rate maps, QT maps, NT maps, PRPD cumulative maps, ϕ-Q-N maps of each signal channel, and can display PD signal amplitude and pulse number of each signal channel . 
  8. Over-limit alarm: the software adopts three-color indication modes of red, yellow and blue, which indicates the severity of partial discharge and facilitates information reading.
  9. Average trouble free time: over 50000hours.
  10. Safety performance: meets GB/T 19862-2005 general requirements for switchgear monitoring equipment.
  11. Electromagnetic compatibility: 
Electrostatic discharge immunity meets level IEC 61000-4-2: 2001
Damped oscillatory magnetic field immunity meets IEC 61000-4-10: 1993 level 3
Power frequency magnetic field immunity meets IEC 61000-4-8: 2001 level 3
Pulse magnetic field immunity meets IEC 61000-4-9: 1993 Level 3
  1. Power supply: powered by 12V lithium battery, power consumption < 20W, sustainable work for more than 6 hours.
  2. Environmental conditions:
Storage temperature: -40ºC ~ +85ºC,
Working temperature: -20ºC ~ +60ºC,
Relative humidity: 5% ~ 95% without condensation at 35ºC
  1. Light weight and easy to carry, it is suitable for field use
Signal acquisition host weight <3kg

Specifications
 
PD signal acquisition host:
CPU Working frequency1.2GHz
Operating systemLinx embedded operating system
Wired network portLAN network port
Wireless network portBuilt-in WiFi
System running memory1G
System storage memory512M
Data acquisition frequency250MHz
Ultrasonic detection channel:
Measurement range0-60mV
Frequency detection range20~200kHz
UHF detection channel:
Detection frequency300~1800MHz
Measurement range-80~10dBm
Error±1dBm
Resolution1dBm
HFCT detection channel
Frequency range0.5~100MHz
Error±1dB
Dynamic Range60dB
Measurement range0-100mV
Accuracy1dB
TEV detection channel
Frequency range3~100MHz
Measurement range0-60dB/mV
Sensitivity0.01mV
Error±1dB/mV
Resolution1dBm/mV
Battery
Built-in batteryLithium battery, 12V, 4000mAh
Use timeabout 8 hours
Charging timeAbout 2 hours
Battery protectionOver-voltage and over-current protection
Battery charger
Rated voltage 12.6V
Charging output current2A
Operating temperature-20ºC-60ºC
Operating humidity<80%
Handheld display terminal (industrial grade) or ThinkPad notebook:
CPUIntel Quad Core Atom Z3735F
GPUIntel HD Graphic (Gen7)
Flash32GB
RAM2GB
Operating systemWindows10
Display8.1 inch 1280×800 IPS screen
Network interfaceWifi and Bluetooth
Battery 3.7V 8500mAH polymer lithium ion battery
Size
PD acquisition host size395mm*295mm*105mm
PD acquisition host weight0.85kg
Display tablet size570mm*360mm*240mm
Display tablet weight0.85kg
Overall box size570mm*360mm*240mm
Working environment
Working temperature-20ºC~50ºC
Environment humidity0~90%RH
IP level54

4 Channel Transformer Switchgear Live Line Partial Discharge Detector
4 Channel Transformer Switchgear Live Line Partial Discharge Detector
4 Channel Transformer Switchgear Live Line Partial Discharge Detector
4 Channel Transformer Switchgear Live Line Partial Discharge Detector
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours