Automatic insulating oil dielectric strength tester breakdown detection transformer oil Bdv test

100KV Transformer oil tester HYYJ-502AIntroductionHYYJ-502A insulating oil tester is developed according to DL/T846.7-2004 "Insulating oil dielectric tester" standard and the IEC/ASTM international standard. Built-in EEPROM memory can save 100 sets of test data, and test results can be printed at any time. It has the a

Featured Products

100KV Transformer oil tester HYYJ-502A

Introduction
HYYJ-502A insulating oil tester is developed according to DL/T846.7-2004 "Insulating oil dielectric tester" standard and the IEC/ASTM international standard. Built-in EEPROM memory can save 100 sets of test data, and test results can be printed at any time. It has the advantages of simple operation, powerful function, stable and reliable, and high degree of automation.


Features
1. All the human interaction operation is controlled through a 7-inch touch screen.
2. The test process fully meets the requirements of IEC156/IS6792/BS5874, ASTMD1816, ASTMD877 and ASTMD1816.
3. Test standards can be selected to set up with high test accuracy.
4. PC application software is provided to upload test data to make WORD test report.

Technical index
1 Voltage OEM for clients 
2 AC220V±10% power supply input 
3 Output voltage:AC 0V~100KV 
4 Rate of voltage rise: 0.5kv/s±10%, 2kv/s±5%, 3kv/s±5%,5kv/s±5% 
5 Max test times: 9 
6 Init wait times:0~999s 
7 Stir time: 0~999s 
8 Wait time: 0~999s 
9 Measurement accuracy: ±(1% of full scale + 2 digits) Resolution:0.1KV 
10 Temperature measurement: 
11 Measurement range : 0°C to 70°C, or better 
12 Temperature resolution : 1°C, or better 
13 Operating temperature : up to 45°C 
14 Storage:100 groups 
15 7 inch colorful LCD with touch pad 
16 Oil test vessel temperature measurement unit 
17 All the selection can be done by touch panel with color LCD.
Automatic Insulating Oil Dielectric Strength Tester Breakdown Detection Transformer Oil Bdv Test
Other products:
Circuit Breaker Analyzer / Contact Resistance Tester / On Load Tap Changer Tester / Circuit Breaker Vacuum Degree Tester / Insulating Oil Tester / CT PT Analyzer / Transformer Winding Resistance Tester / Sweep Frequency Response Analyzer / Transformer Load and No-load tester / Transformer Ratio Tester / Primary Current Injection Test Set / Frequency Adjustable Series Resonance Test Set / High Voltage Divider / High Voltage Generator / VLF tester / Wireless HV Phase Tester / MOA Metal Oxide Arrester MOA Tester / Hipot Tester / Relay Tester / Insulation Tester / Grounding Resistance Tester

Packaging & Shipping
Automatic Insulating Oil Dielectric Strength Tester Breakdown Detection Transformer Oil Bdv Test
Automatic Insulating Oil Dielectric Strength Tester Breakdown Detection Transformer Oil Bdv Test

logistics
Automatic Insulating Oil Dielectric Strength Tester Breakdown Detection Transformer Oil Bdv Test

Certification Show
Automatic Insulating Oil Dielectric Strength Tester Breakdown Detection Transformer Oil Bdv Test

Company Profile
Automatic Insulating Oil Dielectric Strength Tester Breakdown Detection Transformer Oil Bdv Test


Customers Visiting
Automatic Insulating Oil Dielectric Strength Tester Breakdown Detection Transformer Oil Bdv Test


Exhibition
Automatic Insulating Oil Dielectric Strength Tester Breakdown Detection Transformer Oil Bdv Test

Technical Support
Automatic Insulating Oil Dielectric Strength Tester Breakdown Detection Transformer Oil Bdv Test
Automatic Insulating Oil Dielectric Strength Tester Breakdown Detection Transformer Oil Bdv Test



Contact Us

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours
xt/javascript" src="//form.grofrom.com/livechat.js">