Current Transformer CT PT Analyzer, CT Ratio and Phase Error Calibration, 45kv Knee Voltage

Current Transformer CT PT Analyzer,CT Ratio and Phase Error Calibration With 45KV Knee Voltage Application:Tests for current transformer:Excitation curve and parameters testTurns ratio testRatio and phase error testPolarity mark checkWinding resistance measurementSecondary loop burden measurementError line cu

Featured Products

Current Transformer CT PT Analyzer,CT Ratio and Phase Error Calibration With 45KV Knee Voltage
Current Transformer CT PT Analyzer, CT Ratio and Phase Error Calibration with 45kv Knee Voltage

 


Application:

Tests for current transformer:

  • Excitation curve and parameters test

  • Turns ratio test

  • Ratio and phase error test

  • Polarity mark check

  • Winding resistance measurement

  • Secondary loop burden measurement

  • Error line curve test for protection CT

  • Transient CT parameters test

  • CT nameplate guess

  • Saturation hysteresis loop curve measurement

  • Tests for Potencial Transformer:

  • Turns ratio test

  • Ratio error and phase angle error test

  • Polarity test

  • Secondary burden test

  • Winding resistance test

 

Applications of CT/ PT Analyzer:

  • CT nameplate check

  • CT parameters check in work burden

  • CT transient parameters analysis

  • CT ratio and phase error calibration

  • PT routine test

 

Specifications:

Item NameGDVA-405 CE Certificate Automatic Current Transformer CT and PT Potentional Transformer Tester
Test standardsIEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Power supply AC220V±10%, 50/60Hz±10%
Voltage output 0.1~180V (AC)
Current output 0.001~5A(RMS)
Power output 500VA
Max.  knee voltage measurement 45KV
Current measurement
 

 
  Range0~10A (automatically change  range in 0.1/0.4/2/10A)
  Error <±0.1%+0.01%FS
Voltage measurement
 
 Range0~200V (automatically change range in 1V/10V/70V/200V)
 Error< ±0.1%+0.01%FS
Turns ratio measurement Range
  
1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurement  error ±2min
resolution 0.01min
Winding resistance measurement
    
   
Range0~8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm)
Error < 0.2%RDG+0.02%FS
Maximum resolution :  0.1mΩ
Temperature measurement-50~100 Celsius degree; error<3 Celsius degree
CT Secondary burdenRange0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm
   
  
PT Secondary burden

 
Range0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error<0.2%RDG+0.02%FS
Maximum resolution : 0.1ohm
   
PT ratio measurement
Range

1~35000,

1~10000 error<0.1%, 

10000~35000 error<0.2%

PT ratio error measurement :Typical error<0.05%,  Maximum Error<0.1%
PT phase angle measurement maximum error < 3min
Make evaluation for test results according to selected standards
Make word report for test result
Make word reports one time for multi-group test records on the PC
Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
Compare excitation curves with saved excitation curves in the same window
Memory capacity >1000 groups test results
Working condition temperature -10ºC~50ºC; moist ≤90%

Current Transformer CT PT Analyzer, CT Ratio and Phase Error Calibration with 45kv Knee Voltage
CT/PT Analyzer Schematic Diagram

Current Transformer CT PT Analyzer, CT Ratio and Phase Error Calibration with 45kv Knee Voltage
CT Set Up

Current Transformer CT PT Analyzer, CT Ratio and Phase Error Calibration with 45kv Knee Voltage
Excitation Curve

Current Transformer CT PT Analyzer, CT Ratio and Phase Error Calibration with 45kv Knee Voltage
Parameter Set of CT

 
Real Pictures:
Current Transformer CT PT Analyzer, CT Ratio and Phase Error Calibration with 45kv Knee Voltage

Current Transformer CT PT Analyzer, CT Ratio and Phase Error Calibration with 45kv Knee Voltage

 