Simulated insulator partial discharge test device

Power Frequency Partial Discharge Testing Equipment /hipot testerPower Frequency Partial Discharge Testing Equipment /hipot tester is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power sup

Featured Products

Power Frequency Partial Discharge Testing Equipment /hipot tester

Power Frequency Partial Discharge Testing Equipment /hipot tester is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.


Power Frequency Partial Discharge Testing Equipment /hipot tester
Technical Parameter for Test Transformer
Phase :single phase
Frequency:50Hz
Rated capacity:150kVA
Input voltage:0.4kV
Input current:375A       
Output voltage:0~280kV
Output current: 0.53A
Waveform deviation factor:≤3%
Measurement winding voltage ratio:1000:1
Insulation level: low voltage input terminal to ground power frequency voltage withstand level 5kV/1min
Dielectric loss: <0.3%
Noise:≤60dB
Partial discharge: 0-250kV ,the partial discharge is ≤1-3PC; 0-280kV, the partial discharge is ≤3-5pc
Running time: under rated voltage and current,start form environment temperature,can run 30min.
under 2/3 rated voltage and current, continuous running.
Single test transformer impedance :  3%-12%
Waveform deviation factor: <3%


Device for Simulating Partial Discharge Test of Insulator
Power Frequency Partial Discharge Testing Equipment /hipot tester

According to structure , the device can be divided into four type: single phase iron shell type,
single phase iron shell series type, single phase insulating clinger type and single phase insulating clinger series type. Usually single phase iron shell type is suitable for the occasions where voltage capacity is low and easy to carry , or the equipment is fixed and its voltage capacity is high but with low requirement for partial discharge . Single phase insulating clinger type is usually suitable for the occasions where the requirement of partial discharge is high, but low voltage and fixed. Single phase insulating clinger series type is mainly used for the occasions where the requirement of partial discharge is high,and high voltage,large capacity and easy to carry. All above four type can be select by user's requirement.
Device for Simulating Partial Discharge Test of Insulator
Device for Simulating Partial Discharge Test of Insulator
Device for Simulating Partial Discharge Test of Insulator


 