GDSL-BX-200 500A High Voltage Switch Primary Current Injection Tester

I. General Information GDSL-BX-200 Primary Current Injection Test Set, is mainly used for testing current transformer, motor protector, air switch, switch cabinet, circuit breaker, protection screen and etc.  II. Features 1. PVC panel, simple and neat.2. With low power, big capacity autotransformer regulator

Featured Products

I. General Information
 
GDSL-BX-200 Primary Current Injection Test Set, is mainly used for testing current transformer, motor protector, air switch, switch cabinet, circuit breaker, protection screen and etc.
 
 
II. Features
 
1. PVC panel, simple and neat.
2. With low power, big capacity autotransformer regulator and converter inside.
3. Quick connects, lock design, good current-through capability.
4. Built-in quick plug with high safety, to ensure reliable cable connection and improve test efficiency.
5. Current range can be changed, easy to read.
6. Engineering plastics box, dust-proof and waterproof, IP67 class.
7. Portable design, suitable for on-site testing.
8. Damping design, to ensure reliable transportation
9. Zero start function to prevent the test objects from damage caused by high current impulse. The equipment only can be started from zero.
10. Impulse selection function. The required current can be output directly without zero protection function when making quick-break testing for circuit breaker.
11. Accurate measurement. LCD digital indicator to display output current and voltage. The resolution of output current is 1A .
12. Output 0-50A AC current, suitable for over current quick break testing of secondary protection.
13. Action time can be tested synchronously.
14. More calibrations can be series connected at the same time to improve working efficiency .
15. Directly display primary current and secondary current, convenient for CT/PT turn ratios calibration test. (Optional)
 
 
III. Specifications
 
Power supplyAC 220V 50Hz.
Output power3kVA.
Output current500A in series,1000A in parallel.
Output voltage6V in series, 3V in parallel.
Current can be adjusted smoothly and continuously. The accuracy is 1.0%.
Output current is standard sine wave, waveform distortion is less than 5%.
Secondary injection current50A
Output currentRMS continuous adjustable.
The action time of test object can be tested, the lock action time is also can be recorded at the same time.
Test range0.001S-999.999S, resolution 1ms, error: 0.005%, range: ±2digits
Duty Cycle5mins ON, 10mins OFF.

GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
GDSL-BX-200 500A Primary Current Injection Test Set for HV Switch
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours