Htrs-V Transformer Load, No-Load and Capacity Tester / Transformer Power Analyzer

 Brief introduction HTRS-V can test the transformer capacity, type, no-load current, no-load loss, short circuit (load) loss, resistance voltage, etc. It is small in volume, light in weight, in high accuracy, with steady property, easy to operation can replace the traditional testers. It is displayed by LCD, operated by men

Featured Products

Htrs-V Transformer Load, No-Load and Capacity Tester/Transformer Power Analyzer
Htrs-V Transformer Load, No-Load and Capacity Tester/Transformer Power Analyzer
Htrs-V Transformer Load, No-Load and Capacity Tester/Transformer Power Analyzer
Htrs-V Transformer Load, No-Load and Capacity Tester/Transformer Power Analyzer
 
Brief introduction
HTRS-V can test the transformer capacity, type, no-load current, no-load loss, short circuit (load) loss, resistance voltage, etc. It is small in volume, light in weight, in high accuracy, with steady property, easy to operation can replace the traditional testers. It is displayed by LCD, operated by menu, with friendly interface, is the first choice for all customers.
 
Products features
can accurately measure capacity of distribution transformer , convenient and accurate.
Measure the transformer no-load current, no-load loss; short-circuit voltage, short circuit (load) loss, capacity.
The device with auto switching range, allow measure wide range voltage and current, simple wiring;
The device can auto check if the wire was correctly connected, and display the vector diagram of three phase current, voltage when test the three phase transformer.
Single machine can make the loading test for substation transformer under 1000KVA; can make the loading test with 1/3 of the rated current for substation transformer under 3150KVA (the device can convert to the loading losses parameters if the rated current under 1/3 of the rated current)
All the related test results are automatically corrected. Instrument can automatically such as: the waveform correction, temperature correction, non-rated voltage correction, calibration, and other non-rated current correction, so that more accurate test results.
320x240 LCD, friendly man-machine interface, brilliance control, adapts to all seasons.
The device can be preset 40 groups parameters of testes objects, and these parameters can be deleted or added at any time as needed, easy to use.
With electronic clock, auto record the data, time, it is good for saving and managing the test results.
Panel type printer can print the test results on site.
Data (specimen setting, test results, measurement time) can be saved on power failure and can be reviewed, it can store 500 groups test results, can connect with computers to transmit data.
Allow external connecting CT and PT to make extension measurement, can test the specimen with any parameters.
Product parameters
Service conditions
Temperature-5°C~40°C
Humidity<95%(25°C)
Altitude<2500m
Outside interferenceno exceptionally strong vibration, no extra - strong electromagnetic fields.
Power supply220VAC±10%,45Hz~55Hz.
Main technical parameters
Active parts:
Current output0 ~ 10A
Voltage measurement0 ~ 10V
Test Capacity10KV oil-immersed, dry-type transformers: 30KVA ~ 2500KVA
35KV oil-immersed transformers: 50KVA ~ 31500KVA
20KV dry type transformers: 50KVA ~ 2500KVA
35KV dry type transformers: 50KVA ~ 2000KVA
Features parts:
Voltage0~450V (phase voltage), 0 ~ 800V (line voltage),auto-switch the measurement range
Current0 ~ 100A, auto-switch the measurement range
Frequency45Hz ~ 65Hz
Test accuracy
Voltage 20 ~ 100V, ± 0.2% FS; 100 ~ 450V, ± 0.2%
Current0.5 ~ 10A, ± 0.2% FS; 10 ~ 100A, ± 0.2%
Power± 0.5% (CosΦ> 0.1), ± 1.0% (0.02 <CosΦ <0.1)
Dielectric strengthThe insulation resistance between voltage, current input terminal and the chassis≥100MΩ.
Between power supply input terminal and the shell can withstand  2KV (rms), for 1 minute
Dimension400×300×170mm
Weight 6kg (not including test lines)
Htrs-V Transformer Load, No-Load and Capacity Tester/Transformer Power Analyzer
Htrs-V Transformer Load, No-Load and Capacity Tester/Transformer Power Analyzer
Htrs-V Transformer Load, No-Load and Capacity Tester/Transformer Power Analyzer
Htrs-V Transformer Load, No-Load and Capacity Tester/Transformer Power Analyzer
Htrs-V Transformer Load, No-Load and Capacity Tester/Transformer Power Analyzer
Htrs-V Transformer Load, No-Load and Capacity Tester/Transformer Power Analyzer
Htrs-V Transformer Load, No-Load and Capacity Tester/Transformer Power Analyzer

Common problem
1. Is your company a sales company or a manufacturer?
Wuhan Huatian Electric Power Automation CO., LTD.is an industrial and trade enterprise, with its own  factory, self-produced and self-sold. We were founded in 2004 and have fifteen years of production experience. Our company has reliable production lines, test rooms and R&D centers.

2. Whether the goods are in stock, whether they can be customized, and how long the delivery time is.
After the goods have been ordered, we can be made to order according to the special requirements of customers by using the latest technology. The delivery time is usually within 10 working days if there are no accidents.

3. Is the quality guaranteed?
In order to ensure quality, we use imported components in large quantities. After three times of quality inspection, the goods can be sent out, and the export is uniformly packed in non-fumigation wooden boxes.

4. What are the after-sales terms?
We offer free consulting service, one year warranty, and adopt various methods such as email communication, video calls, technology door-to-door, aiming to solve any after-sales problems in a timely manner.

5. What are the cooperative countries or regions?
Products have been successfully exported to the United States, Brazil, Australia, Russia, the Netherlands, Indonesia, Bangladesh, Iran, India, Saudi Arabia, Mongolia, Japan and other countries and regions. In the United States, India, Vietnam and other regions have cooperative distributors, can provide thoughtful services.



Contact us

Wuhan Huatian Electric Power Automation CO., LTD


Address: T4, No. 1, High-tech 2 Road,East Lake High-tech Development Zone,Wuhan
Zip code: 430074
Tel:(+86)-27-8745 7960 / (+86)027-87993136 / 13808601259
Fax: (+86)-27-8799 3136
 

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours