Oil Transformer Insulation Cardboard Oil Fence Spacing/Transformer Winding Oil Pipe

Introduction Insulation class: A (105 °C) 100% sulphate wood pulp Natural-color Precompressed pressboard, even fiber orientation, hard and dimensionally stable High purity and mechanical strength Low shrinkage, fiber-free surface Good compatibility with liquid dielectrics Product

Featured Products

Introduction
 Insulation class: A (105 °C)
 100% sulphate wood pulp
 Natural-color
 Precompressed pressboard, even fiber orientation, hard and dimensionally stable
 High purity and mechanical strength
 Low shrinkage, fiber-free surface
 Good compatibility with liquid dielectrics
 
Product Description
Description and feature:
Duct strip is made from high quality pressboard G4 grade. It has excellent transformer oil impregnation feature, high compressive strength more than corrugated pressboard which is the old technology. It is used at high temperature condition and it could be improved the circuit strength.The character are below:
1. High mechanic strength
2. High electric strength
3. Accurate dimension
Insulation Pressboard Oil Grid Spacing for Oil Transformer/ Oil Duct for Transformer Winding



 
Application:  
Oil duct strip provides duct for the flow of the cooling oil in layer and strip windings in distribution power transformers. It is manufactured by bonding transformer board sticks onto insulating paper or single-coated diamond dotted paper.
Main strips: Rectangular strips, T-strips, Pigeon cauda strips, Abnormity strips.

It is used in Oil-immersed Transformers for insulation between coils. The advantage with partially coated insulation press paper lies in the internal strengthening of the coil from adhesion to the conductor; this provides passage for quick evacuation of air and moisture during the drying process. It also minimizes the risk of partial discharge,quick impregnation and flow of oil through the channels. The bonding strength of the epoxy resin is sufficient to prevent displacement of winding layers due to short circuit forces.

Insulation Pressboard Oil Grid Spacing for Oil Transformer/ Oil Duct for Transformer Winding

 
 
TRANSFORMER OIL DUCT STRIP DATA SHEET
PART1: PRESSBOARD STICK4*5*1000MM
ITEMTYPICAL VALUESMATTER OF FACT
Thickness: mm4mm±7.5%4.1-4.3mm≤7.5%
Width 5±0.5mm4.95-5.38mm≤0.4mm
Length of 1000mm:±5mm1000±3 mm 
Pitch of stick centre:±3mm23±2 mm
Apparent density: g/cm31.1-1.21.18
Moisture content ,%4.0 to 9.0%5.7
PH water extract:6.0 to 9.06.8
Ash content,%    maximum1%0.51
Tensile strength  Mpa
Machine direction:
Cross machine direction:
 
≥90
≥50
 
107.4
101.3
Oil absorption ≥7.0%12.29
Shrinkage rate% MD
              CMD
         Thickness D
≤1.0
≤1.4
≤6.0
0.16
0.25
≤5
Elongation rate  MD
              CMD
≥3
≥4
≥4.4
≥4.4
Conductivity of aqueous extract Ms/m≤10.05.03
Dielectric breakdown:(Kv/mm )In Air
In Oil
10
24
16.7
35.7

 
PART2: SINGLE SIDE DIAMOND DOTTED PAPER DATA SHEET
ITEMTYPICAL VALUESMATTER OF FACT
Caliper:  (millimeter)0.25mm
Thickness: mm0.25±0.025mm+0.060.260
(0.260,0.258,0.262)
Width: mm1000±5mm1000-1005
Apparent density: g/cm30.9 to 1.11.01
Moisture content ,%4.0 to 8.0%5.6
PH water extract: 6.0 to 8.07.5
Ash content,%    maximum1%0. 43
Coating thickness per side mm0.006 to 0.0120.011
Tensile strength,N/mm2 
Machine direction: 
Cross machine direction: 
 
80
35
 
86.6
48.1
Dielectric breakdown: 
(volts/layer ,dry test)
≥21002230
Bond strength: Kpa450kpa679
    

welcome all inquiry
 