Htfa-102 Current Transformer Analyzer CT PT Excitation Curve Test

Product overviewThe products put into the market after a lot of market researches, strict field tests and the authoritative department identification by our R & D team. Instrument adopts high performance data processing and microcomputer control architecture, advanced manufacturing process, to ensure the product performance

Featured Products

Htfa-102 Current Transformer Analysis Device CT PT Excitation Curve Testing
Htfa-102 Current Transformer Analysis Device CT PT Excitation Curve Testing
Htfa-102 Current Transformer Analysis Device CT PT Excitation Curve Testing
Htfa-102 Current Transformer Analysis Device CT PT Excitation Curve Testing

Product overview
The products put into the market after a lot of market researches, strict field tests and the authoritative department identification by our R & D team. Instrument adopts high performance data processing and microcomputer control architecture, advanced manufacturing process, to ensure the product performance stable and reliable, fully functional, high degree of automation, high test efficiency, is a professional protection box of high voltage insulation used to test current voltage transformers specialized detection equipment.

Products features

1. Safe and convenient to operate: Full micro-computerized devices, built-in imported high-performance CPU, with high reliability, according the prompt of the interface to set test values, you need not touch the tested equipment, the equipment automatically finish the test, the test personnel far from high voltage circuit ,to ensure their personal safety.
2. Full-featured: The instrument set includes CT volt-ampere characteristic test, CT variable ratio polarity test, CT polarity test and CT one-pass current test. It automatically calculates the inflection point voltage and current value, ratio difference value, 5% or 10% error curve value, and saves the print test record and date in real time, so as to facilitate users to organize test reports.
3. High output capacity: the maximum output voltage for volt-ampere characteristic tests up to 1000V, the maximum current for ratio test up to 600A, the output capacity of equipment is 5KVA.
4. Large-screen 320 × 240 dot matrix character graphical interface, directly display volt-ampere characteristic curve after the test, graphics are clear, aesthetic, easy to analyze, equipped with micro-printer, can print the curves and test results at any time.
5. Built-in Flash memory device can store large amounts of test data, which will not be lost after power off. When the filed tests finished, people can check and print the tests results indoors.
6. U-disk dump: support U disk to dump test data, through PC to read, easy to operate.
7. PC with powerful software, beautiful outlook, easy to operate, can save and print the test results, convenient to manage the test data.

8. Apparatus can achieve AC220V and AC380V adaptive power supply. When the AC power input terminals connected to AC220V voltage, AC voltage output is 0 ~ 600 V, when the input terminals to AC380V voltage, AC voltage output is 0 ~ 1000 V. Users can choose according to actual needs.

Technique parameters
Power supplyAC380VAC220V
CT volt-ampere characteristic teststand-alone 0~1000V,0~20A0~600V,0~20A
external booster(optional)0~2500V,0~3A0~2000V,0~3A
Resolution0.1V,1mA
Accuracy≤0.5%
5% or 10% error curveAccuracy≤1.0%
CT ratio testRange5~25000A/5A(5000A/1A)
Accuracy≤1.0%
AC withstand voltagestand-alone 0~1000V0~600V
external booster(optional)0~2500V0~2000V
Accuracy0.1V
PT ratio polarity testRange1~10000
Accuracy≤1.0%
Primary current injectingCurrent Range0~600A
current injecting time5min
Power supply voltageAC220V or AC380V 50HZ
Working environment temperature-10ºC ~ +50ºC
host volume420×330×320
host weight39kg
external booster (optional)volume310×310×330
external booster (optional)weight25kg
Htfa-102 Current Transformer Analysis Device CT PT Excitation Curve Testing
Htfa-102 Current Transformer Analysis Device CT PT Excitation Curve Testing
Htfa-102 Current Transformer Analysis Device CT PT Excitation Curve Testing
Htfa-102 Current Transformer Analysis Device CT PT Excitation Curve Testing
Htfa-102 Current Transformer Analysis Device CT PT Excitation Curve Testing
Htfa-102 Current Transformer Analysis Device CT PT Excitation Curve Testing
Htfa-102 Current Transformer Analysis Device CT PT Excitation Curve Testing

Common problem
1. Is your company a sales company or a manufacturer?
Wuhan Huatian Electric Power Automation CO., LTD.is an industrial and trade enterprise, with its own  factory, self-produced and self-sold. We were founded in 2004 and have fifteen years of production experience. Our company has reliable production lines, test rooms and R&D centers.

2. Whether the goods are in stock, whether they can be customized, and how long the delivery time is.
After the goods have been ordered, we can be made to order according to the special requirements of customers by using the latest technology. The delivery time is usually within 10 working days if there are no accidents.

3. Is the quality guaranteed?
In order to ensure quality, we use imported components in large quantities. After three times of quality inspection, the goods can be sent out, and the export is uniformly packed in non-fumigation wooden boxes.

4. What are the after-sales terms?
We offer free consulting service, one year warranty, and adopt various methods such as email communication, video calls, technology door-to-door, aiming to solve any after-sales problems in a timely manner.

5. What are the cooperative countries or regions?
Products have been successfully exported to the United States, Brazil, Australia, Russia, the Netherlands, Indonesia, Bangladesh, Iran, India, Saudi Arabia, Mongolia, Japan and other countries and regions. In the United States, India, Vietnam and other regions have cooperative distributors, can provide thoughtful services.



Contact us

Wuhan Huatian Electric Power Automation CO., LTD


Address: T4, No. 1, High-tech 2 Road,East Lake High-tech Development Zone,Wuhan
Zip code: 430074
Tel:(+86)-27-8745 7960 / (+86)027-87993136 / 13808601259
Fax: (+86)-27-8799 3136
 

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours