Transformer Oil Dielectric Loss Tester/Transformer Loss Factor Tester

Transformer Oil Dielectric Loss Tester/Transformer Dissipation Factor TesterIntroductionIntelligent tgδ Meter is a kind of instrument with high precision fully automatic measuring the dielectric loss tangent and capacitance of various high voltage electrical equipment in th

Featured Products

Transformer Oil Dielectric Loss Tester/Transformer Dissipation Factor Tester

Transformer Oil Dielectric Loss Tester/Transformer Dissipation Factor Tester
Transformer Oil Dielectric Loss Tester/Transformer Dissipation Factor Tester



Introduction
  1. Intelligent tgδ Meter is a kind of instrument with high precision fully automatic measuring the dielectric loss tangent and capacitance of various high voltage electrical equipment in the power plants and substations. The adoption of frequency conversion technology could ensure the accurate measurement in the interference of strong electric field.
  2. The operation instruction of the instrument is English. The whole process is measured automatically through microcomputer.
  3. The instrument also applies to the measurement of tgδ and electrical capacity of high voltage electrical equipment in the workshops, laboratories and research institutes.
  4. Transformer Oil Dielectric Loss Tester/Transformer Dissipation Factor Tester could measure non-grounded or grounded high voltage equipment adopting positive and negative connection method. Besides, it could measure the tgδ of capacitor voltage transformer and capacitance of main capacitor C1and C2.
  5. Transformer Oil Dielectric Loss Tester/Transformer Dissipation Factor Tester is equipped with high voltage step-up transformer. Besides, it takes security measures like zero-cross closing, lightning protection, etc. During the experiment, different levels of high voltage ranging from 0.5KV to 10kV are outputted. The instrument has the advantages of convenient and safe operation.
  6. Under the circumstance of oil dielectric loss ≥ 0.01%, with oil cup, positive wiring can be used to measure the dielectric loss of oil.

 

This following protection features are not included in this instrument:

• High voltage short-circuit protection

• CVT over-voltage protection

• Poor grounding protection


Technical Index
 

High voltage output

0.5~10kV

Increasing by 500V for each level, a total of 20 levels, capacity: 1500VA

Accuracy

tgδ: ± (reading *1.5% +0.06%)

Cx: ± (reading * 1.5% +5 PF)

Resolution

tgδ: 0.001%   Cx: 0.001pF

Measuring range

0.001% 100%;

Internal high pressure : 3PF ~60000PF/10KV,    60PF~1µF/0.5KV

External high pressure: 3PF ~1.5µF/10KV,       60PF~30µF/0.5KV

 

CVT Variable ratio test

Variation ratio measurement accuracy: ± reading *1%

The range of the measurement: 10~99999

Phase measurement accuracy: ±0.1°

Phase measurement range: 0~359.9°

Power supply AC 220V ± 10%   50/60 ± 1Hz
 

Measuring method

a.single frequency: 45(45Hz measuring),50(50Hz measuring),55(55Hz  

measuring),60(60Hz measuring),65(65Hz measuring)

b.different frequency: 50D(45Hz/55Hz measure each time);

                                   60D(55Hz/65Hz measure each time);                                                                     Automatic frequency conversion

Harmonic adaptation ≤ 3%
Application condition -15 ºC-50 ºC Relative humidity <80%
Dimension 460 (L) * 345 (W)* 345 (H)

Weight

35 kg


10KV High Voltage Output
Transformer Oil Dielectric Loss Tester/Transformer Dissipation Factor Tester
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours